TF-95LG

TF-95LG
Nitrile Exam Gloves with EnerGel®
-
Low Dermatitis Potential
-
SHA Approved
-
UL Classified
-
Instruction for Use
-
EN Food Safe
-
ISO 374-1:2016 Type B JKT
-
EN374-5:2016 VIRUS
-
CE 0493
• EnerGel Hand Conditioning Technology hydrates and soothes skin
• Fully textured surface delivers added grip
• Beaded cuff allows easy donning and doffing
• 100% air inspected / consistent thickness tip to cuff
Description
Featuring an EnerGel inner coating, these gloves soothe and moisturize dry hands without sacrificing dexterity.
Features and Benefits
- EnerGel® Hand Conditioning Technology hydrates and soothes skin
- Optimal thickness for durability and tactile sensitivity
- Fully textured surface for excellent wet and dry grip
- Touch-screen compatible
- Tear-resistant beaded cuff eases donning
- SHA Dermatologically Approved
- 1.5 AQL exceeds laboratory standards
Typical Applications
For Medical Use
Chemical Handling
Clinical
First Responder EMS
Handling and Packaging Class 1 Medical Devices
Laboratory
Light Chemical Mixing
Liquid Handling
Pharma Production
Product Technologies
EnerGel
Yes
Specifications
Glove Type
Single-Use
Fit Type
Ambidextrous
Grade
Powder-Free Exam
Material
Nitrile
Finger Thickness mil
4.0mil
Finger Thickness mm
0.10mm
Palm Thickness mil
3.6mil
Palm Thickness mm
0.09mm
Cuff Thickness mil
3.0mil
Cuff Thickness mm
0.08mm
Color Outer
Light Green
Surface Outer
Fully Textured
Surface Inner
EnerGel
Length inch
9.5"
Length mm
242mm
Palm Width inch
4.2"
Palm Width mm
107mm
Weight in Grams
5.0g
Cuff Type
Beaded
AQL
1.5
Country Origin
China
Other
Silicone Free
Yes
Industries
Life Science
Yes
Healthcare
Yes
Industrial
Yes
Automotive After Market
Yes
Performance
Tensile Before
22 MPa
Tensile After
20 MPa
Elongation Before
560%
Elongation After
550%
Size | Item Number | UPC Number | Packaging Unit |
---|---|---|---|
XS (5 ½ - 6) | N128401 | 0130616489100219 | 100/Bx 1000/Cs |
S (6 ½ - 7) | N128402 | 0130616489100226 | 100/Bx 1000/Cs |
M (7 ½ - 8) | N128403 | 0130616489100233 | 100/Bx 1000/Cs |
L (8 ½ - 9) | N128404 | 0130616489100240 | 100/Bx 1000/Cs |
XL (9 ½ - 10) | N128405 | 0130616489100257 | 100/Bx 1000/Cs |
Documents |
|
TF-050-095-NRG-LG Datasheet |
ANSI-ISEA-105 Chemical Permeation Breakthrough Times
Chemical | CAS No. | Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 | ANSI-ISEA 105 Level | Report No. |
---|---|---|---|---|
Acetic Acid (Glacial) | 64-19-7 | 8 | 0 | |
Hydrochloric Acid (37% | 7647-01-0 | 10 | 0 | |
Nitric Acid (70%) | 7697-37-2 | 7 | 0 | |
Sulfuric Acid (96%) | 7664-93-9 | 6 | 0 | |
Phosphoric acid (85%) | 7664-38-2 | >240 | 5 | |
Ammonium Hydroxide (25%) | 1336-21-6 | 54 | 2 | |
Sodium Hydroxide (40%) | 1310-73-2 | >240 | 5 | |
Benzene | 71-43-2 | 0 | 0 | |
Butyl Acetate | 123-86-4 | <5 | 0 | |
Chloroform | 67-66-3 | <5 | 0 | |
DMSO | 67-68-5 | <5 | 0 | |
Heptane | 142-82-5 | 34 | 2 | |
Hexane | 110-54-3 | 39 | 2 | |
Petroleum ether | 8032-32-4 | 35 | 2 | |
Stoddard Solvent | 68797-94-4 | 14 | 1 | |
Xylene | 1330-20-7 | <5 | 0 | |
Acetone | 67-64-1 | <5 | 0 | |
Acetonitrile | 75-05-8 | <5 | 0 | |
Cyclohexanone | 108-94-1 | <5 | 0 | |
2-butoxyethanol | 111-76-2 | 28 | 1 | |
Diacetone alcohol | 123-42-2 | 25 | 1 | |
Ethyl alcohol | 64-17-5 | <5 | 0 | |
Isopropyl alcohol | 67-56-1 | 25 | 1 | |
Methanol | 67-63-0 | <5 | 0 |
The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the ANSI-ISEA 105 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.
EN374-3 Chemical Permeation Breakthrough Times
Chemical | CAS No. | Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 | EN374-3 Level | Report No. |
---|---|---|---|---|
Acetic Acid (Glacial) | 64-19-7 | <5 | 0 | |
Hydrochloric Acid (37%) | 7647-01-0 | 13 | 1 | |
Nitric Acid (70%) | 7697-37-2 | 7 | 0 | |
Sulfuric Acid (96%) | 7664-93-9 | 5 | 0 | |
Phosphoric acid (85%) | 7664-38-2 | >240 | 5 | |
Ammonium Hydroxide (25%) | 1336-21-6 | 56 | 2 | |
Sodium Hydroxide (40%) | 1310-73-2 | >240 | 5 | |
Benzene | 71-43-2 | 0 | 0 | |
Butyl Acetate | 123-86-4 | 0 | 0 | |
Chloroform | 67-66-3 | 0 | 0 | |
DMSO | 67-68-5 | <5 | 0 | |
Heptane | 142-82-5 | 47 | 2 | |
Hexane | 110-54-3 | 38 | 2 | |
Petroleum ether | 8032-32-4 | 39 | 2 | |
Stoddard Solvent | 68797-94-4 | 11 | 1 | |
Xylene | 1330-20-7 | <5 | 0 | |
Acetone | 67-64-1 | 0 | 0 | |
Acetonitrile | 75-05-8 | 0 | 0 | |
Cyclohexanone | 108-94-1 | <5 | 0 | |
2-butoxyethanol | 111-76-2 | 26 | 1 | |
Diacetone alcohol | 123-42-2 | 24 | 1 | |
Ethyl alcohol | 64-17-5 | <5 | 0 | |
Isopropyl alcohol | 67-56-1 | 24 | 1 | |
Methanol | 67-63-0 | <5 | 0 |
The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the EN374-3 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.
Product Technologies
![]() Hydrates and rejuvenates hands for all-day comfort. New patented additive clinically proven to improve hand health. |
PHOTOS |
Coming soon!
Coming soon!