TF-12LG

TF-12LG

Extended Cuff Nitrile Exam Gloves

  • Low Dermatitis Potential
    Low Dermatitis Potential
  • SHA Approved
    SHA Approved
  • UL Classified
    UL Classified
  • Instruction for Use
    Instruction for Use
  • EN Food Safe
    EN Food Safe
  • ISO 374-1:2016 Type B JKT
    ISO 374-1:2016 Type B JKT
  • EN374-5:2016 VIRUS
    EN374-5:2016 VIRUS
  • CE 0493
    CE 0493

• Extra length cuff provides additional protection
• Fully textured surface delivers added grip
• 100% air inspected / consistent thickness tip to cuff

TF-12LG

Description

These gloves provide tactile sensitivity and great grip with an extended cuff for added protection, so you can work in comfort and confidence.

Features and Benefits

• Optimal thickness for durability and tactile sensitivity
• Fully textured surface for excellent wet and dry grip
• Extended cuff provides added protection
• Tear-resistant beaded cuff eases donning
• SHA Dermatologically Approved
• 1.5 AQL exceeds laboratory standards
EcoTek Sustainable Technology

 

Typical Applications

For Medical Use
Chemical Handling
Clinical
Handling and Packaging Class 1 Medical Devices
Laboratory
Light Chemical Mixing
Pharma Production

Specifications

Glove Type

Single-Use

Fit Type

Ambidextrous

Grade

Powder-Free Exam

Material

Nitrile

Finger Thickness mil

5.9mil

Finger Thickness mm

0.15mm

Palm Thickness mil

4.9mil

Palm Thickness mm

0.12mm

Cuff Thickness mil

3.6mil

Cuff Thickness mm

0.09mm

Color Outer

Light Green

Surface Outer

Fully Textured

Length inch

12"

Length mm

305mm

Palm Width inch

4.2"

Palm Width mm

108mm

Weight in Grams

7.5g

Cuff Type

Beaded

AQL

1.5

Country Origin

China/Malaysia

Other

Silicone Free

Yes

Industries

Life Science

Yes

Healthcare

Yes

Industrial

Yes

Automotive After Market

Yes

Performance

Tensile Before

21 MPa

Tensile After

19 MPa

Elongation Before

580%

Elongation After

550%

Size Item Number UPC Number Packaging Unit
XS (5 ½ - 6) N027401 0130616489002711 100/Bx 1000/Cs
S (6 ½ - 7) N027402 0130616489002728 100/Bx 1000/Cs
M (7 ½ - 8) N027403 0130616489002735 100/Bx 1000/Cs
L (8 ½ - 9) N027404 0130616489002742 100/Bx 1000/Cs
XL (9 ½ - 10) N027405 0130616489002759 100/Bx 1000/Cs
2XL (10 ½ - 11) N027406 0130616489002766 90/Bx 900/Cs

ANSI-ISEA-105 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 ANSI-ISEA 105 Level Report No.
Acetic Acid (Glacial 64-19-7 15 1
Citric Acid (50%) 77-92-9 >240 5
Hydrochloric Acid (37%) 7647-01-0 20 1
Hydrochloric Acid (20%) 7647-01-0 >240 5
Perchloric Acid (70%) 7601-90-3 >30 2
Nitric Acid (70%) 7697-37-2 13 1
Sulfuric Acid (96%) 7664-93-9 11 1
Sulfuric Acid (50%) 7664-93-9 >240 5
Phosphoric acid (85%) 7664-38-2 >240 5
Hydrogen Peroxide (30%) 7722-84-1 >10 1
Ammonium Hydroxide (25%) 1336-21-6 95 3
Sodium Hydroxide (40%) 1310-73-2 >240 5
Sodium Hypochlorite 7681-52-9 >240 5
Ethidim Bromide (5%) 1239-45-8 >240 5
Chloroform 67-66-3 <5 0
DMSO 67-68-5 <5 0
DMSO (10%) 67-68-5 >10 2
Heptane 142-82-5 79 3
Hexane 110-54-3 49 2
Petroleum ether 8032-32-4 37 2
Stoddard Solvent 8052-41-3 21 1
Phenol (0.5%) 108-95-2 >30 2
Xylene 1330-20-7 <5 0
Acetone 67-64-1 <5 0
Acetonitrile 75-05-8 <5 0
Formalin / Formaldehyde 37% 50-00-0 >240 5
2-butoxyethanol 111-76-2 27 1
Diacetone alcohol 123-42-2 15 1
Ethyl alcohol / Ethanol (99%) 64-17-5 <10 0
Ethyl alcohol / Ethanol (70%) 64-68-5 >10 1
Isopropanol / IPA (99%) 67-63-0 53 2
Methanol 67-56-1 <5 0

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the ANSI-ISEA 105 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.

EN374-3 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 EN374-3 Level Report No.
Acetic Acid (Glacial) 64-19-7 13 1
Citric Acid (50%) 77-92-9 >240 5
Hydrochloric Acid (37%) 7647-01-0 18 1
Hydrochloric Acid (20%) 7647-01-0 >240 5
Perchloric Acid (70%) 7601-90-3 >30 2
Nitric Acid (70%) 7697-37-2 16 1
Sulfuric Acid (96%) 7664-93-9 12 1
Sulfuric Acid (50%) 7664-93-9 >240 5
Phosphoric acid (85%) 7664-38-2 >240 5
Hydrogen Peroxide (30%) 7722-84-1 >30 2
Ammonium Hydroxide (25%) 1336-21-6 108 3
Sodium Hydroxide (40%) 1310-73-2 >240 5
Sodium Hypochlorite 7681-52-9 >240 5
Ethidim Bromide (5%) 1239-45-8 >240 5
Chloroform 67-66-3 0 0
DMSO 67-68-5 <5 0
DMSO (10%) 67-68-5 >10 2
Heptane 142-82-5 76 3
Hexane 110-54-3 56 2
Petroleum ether 8032-32-4 47 2
Stoddard Solvent 8052-41-3 18 1
Phenol (0.5%) 108-95-2 >30 2
Xylene 1330-20-7 <5 0
Acetone 67-64-1 0 0
Acetonitrile 75-05-8 0 0
Formalin / Formaldehyde 37% 50-00-0 >240 5
2-butoxyethanol 111-76-2 24 1
Diacetone alcohol 123-42-2 11 1
Ethyl alcohol / Ethanol (99%) 64-17-5 <10 0
Ethyl alcohol / Ethanol (70%) 64-68-5 >10 1
Isopropanol / IPA (99%) 67-63-0 50 2
Methanol 67-56-1 <5 0

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the EN374-3 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.