PC-12WT

PC-12WT

(NEW)
EcoTek Sustainable Nitrile Cleanroom Gloves

  • Low Dermatitis Potential
    Low Dermatitis Potential
  • SHA Approved
    SHA Approved

• Finger textured surface delivers excellent grip
• Tear-resistant beaded cuff for easy donning
• Extended-cuff for added coverage and protection

PC-12WT

Description

High-performance nitrile cleanroom gloves deliver exceptional durability, chemical resistance, and particulate control for controlled environments.

Standards – Compliance

ISO 14644-9:2012
IEST-RP-CC005.4
ASTM D6319-19
ASTM D5151-19
ASTM D6978-05(2019)
ASTM F1671-13
EN ISO 21420:2020
EN 374:2016+A1:2018
EN 455-2000-2015
EN ISO 23464:2020
ASTM F739-12
Reach EU 1907/2006
EU 2016/425
FDA 21 CFR 177.2600

Features and Benefits

• EcoTek® Sustainable Technology*
• SafeDon® dispensing minimizes cross-contamination while delivering significant space and packaging savings. (Save over 40% on space and storage and reduce cardboard waste by 20% compared to conventional 100-glove boxes.)
• Low Dermatitis Potential (LDP) minimizes the risk of Type I and Type IV allergies and enhances safety for users with sensitive skin
• Class 100 (ISO 5) cleanroom gloves
• Extended-cuff for additional protection
• Optimal thickness for durability and tactile sensitivity
• Tear-resistant beaded cuff eases donning
• Finger textured surface delivers excellent grip
• Extended-cuff for added coverage and protection
• SHA Dermatologically Approved
• 1.5 AQL for wet and dry environments

Typical Applications

High-Tech Industry Manufacturing
Electronic Component Manufacturing
Semiconductor Production
Precision Circuit Board Assembly
Chip Manufacturing
Medical Operations
Laboratory Operations
Food Processing
Cosmetic Packaging
Electronics Factories
Pharmaceutical
Medical Devices Manufacturing
Biotechnology

Product Technologies

EcoTek

Yes

Specifications

Glove Type

Single-Use

Fit Type

Ambidextrous

Grade

Industrial

Material

Nitrile

Finger Thickness mil

6.2mil

Finger Thickness mm

0.15mm

Palm Thickness mil

5.0mil

Palm Thickness mm

0.12mm

Cuff Thickness mil

4.0mil

Cuff Thickness mm

0.10mm

Color Outer

White

Surface Outer

Finger Textured

Length inch

12.0"

Length mm

290mm

Palm Width inch

4.1"

Palm Width mm

105mm

Weight in Grams

8.0g

Cuff Type

Beaded

AQL

1.5

Country Origin

Malaysia

Performance

Tensile Before

14 MPa

Tensile After

14 MPa

Elongation Before

500%

Elongation After

400%

Cleanroom Class

Class 100 ISO 5

Particle Count (Particle Size ≥ 0.5 Micrometer)

<1200 Counts/Cm²

Fluoride

ND (Not Detected)

Chloride

<0.5

Bromide

ND (Not Detected)

Nitrate

<0.2

Phosphate

ND (Not Detected)

Sulfate

ND (Not Detected)

Sodium

<0.5

Magnesium

ND (Not Detected)

Potassium

<0.5

Silicone

ND (Not Detected)

Amide

ND (Not Detected)

Dioctyl Phthalate (DOP)

ND (Not Detected)

Size Item Number UPC Number Packaging Unit
S (6 ½ - 7) N427102 100 Gloves/Bag, 10 Bags/Case
M (7 ½ - 8) N427103 100 Gloves/Bag, 10 Bags/Case
L (8 ½ - 9) N427104 100 Gloves/Bag, 10 Bags/Case
XL (9 ½ - 10) N427105 100 Gloves/Bag, 10 Bags/Case

ANSI-ISEA-105 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 ANSI-ISEA 105 Level Report No.
Acetic Acid (Glacial) 64-19-7 5 0
Citric Acid (50%) 77-92-9 >240 5
Hydrochloric Acid (37%) 7647-01-0 <5 0
Hydrochloric Acid (20%) 7647-01-0 >240 5
Perchloric Acid (70%) 7601-90-3 >60 3
Nitric Acid (70%) 7697-37-2 <5 0
Sulfuric Acid (96%) 7664-93-9 <5 0
Sulfuric Acid (50%) 7664-93-9 >240 5
Phosphoric acid (85%) 7664-38-2 >240 5
Hydrogen Peroxide (30%) 7722-84-1 >30 2
Ammonium Hydroxide (25%) 1336-21-6 22 2
Sodium Hydroxide (40%) 1310-73-2 >240 5
Sodium Hypochlorite 7681-52-9 >240 5
Ethidim Bromide (5%) 1239-45-8 >240 5
Chloroform 67-66-3 <5 0
DMSO 67-68-5 <5 0
DMSO (10%) 67-68-5 >10 2
Heptane 142-82-5 >30 3
Hexane 110-54-3 10 1
Petroleum ether 8032-32-4 15 1
Stoddart Solvent 8052-41-3 5 0
Phenol (0.5%) 108-95-2 >30 3
Xylene 1330-20-7 <5 0
Acetone 67-64-1 <5 0
Acetonitrile 75-05-8 <5 0
Formalin / Formaldehyde 37% 50-00-0 >240 5
2-butoxyethanol 111-76-2 30 2
Diacetone alcohol 123-42-2 20 2
Ethyl alcohol / Ethanol (99%) 64-17-5 10 1
Ethyl alcohol / Ethanol (70%) 64-68-5 >10 2
Isopropanol / IPA (99%) 67-63-0 15 1
Methanol 67-56-1 <5 0

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the ANSI-ISEA 105 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swssglobal.com.

EN374-3 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Minimum (Minutes) EN 16523-1 EN374-3 Level Report No.
Acetic Acid (Glacial) 64-19-7 5 0
Citric Acid (50%) 77-92-9 >240 5
Hydrochloric Acid (37%) 7647-01-0 <5 0
Hydrochloric Acid (20%) 7647-01-0 >240 5
Perchloric Acid (70%) 7601-90-3 >60 3
Nitric Acid (70%) 7697-37-2 <5 0
Sulfuric Acid (96%) 7664-93-9 <5 0
Sulfuric Acid (50%) 7664-93-9 >240 5
Phosphoric acid (85%) 7664-38-2 >240 5
Hydrogen Peroxide (30%) 7722-84-1 >30 2
Ammonium Hydroxide (25%) 1336-21-6 25 2
Sodium Hydroxide (40%) 1310-73-2 >240 5
Sodium Hypochlorite 7681-52-9 >240 5
Ethidim Bromide (5%) 1239-45-8 >240 5
Chloroform 67-66-3 <5 0
DMSO 67-68-5 <5 0
DMSO (10%) 67-68-5 24 2
Heptane 142-82-5 >30 3
Hexane 110-54-3 10 1
Petroleum ether 8032-32-4 18 1
Stoddart Solvent 8052-41-3 5 0
Phenol (0.5%) 108-95-2 >30 3
Xylene 1330-20-7 <5 0
Acetone 67-64-1 <5 0
Acetonitrile 75-05-8 <5 0
Formalin / Formaldehyde 37% 50-00-0 >240 5
2-butoxyethanol 111-76-2 30 2
Diacetone alcohol 123-42-2 20 2
Ethyl alcohol / Ethanol (99%) 64-17-5 10 1
Ethyl alcohol / Ethanol (70%) 64-68-5 >10 2
Isopropanol / IPA (99%) 67-63-0 15 1
Methanol 67-56-1 <5 0

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with EN 16523-1:2015 and reported according to the EN374-1 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swssglobal.com.

Product Technologies

Sustainable nitrile technology without performance loss.