PF-95GY

PF-95GY

Nitrile Exam Gloves with DriTek® and EcoTek®

  • Chemotherapy Tested
    Chemotherapy Tested
  • Fentanyl & Gastric Acid Tested
    Fentanyl & Gastric Acid Tested
  • SHA Approved
    SHA Approved
  • British Safety Industrial Federation
    British Safety Industrial Federation
  • Instruction for Use
    Instruction for Use
  • EN Food Safe
    EN Food Safe
  • ISO 374-1:2016 Type B JKT
    ISO 374-1:2016 Type B JKT
  • EN374-5:2016 VIRUS
    EN374-5:2016 VIRUS
  • EN388:2016 - 2000X
    EN388:2016 - 2000X
  • CE 0493
    CE 0493

• DriTek absorbent lining keeps hands dry and cool
• Fully textured surface delivers excellent grip
• 100% air inspected / consistent thickness tip to cuff
• EcoTek technology breaks down in landfills in less time

PF-95GY

Description

Work with confidence and comfort in environmentally conscious sustainable gloves with our exclusive DriTek sweat management technology.

Features and Benefits

  • DriTek® Comfort Technology with absorbent lining that wicks away moisture for added extended use
  • EcoTek® Sustainable Technology without any performance loss
  • Fully textured for secure grip
  • Silicone-free for critical environments
  • 1.5 AQL exceeds laboratory standards
  • ANSI 1 Puncture resistance

Typical Applications

For Medical Use

Product Technologies

EcoTek

Yes

DriTek

Yes

Specifications

Glove Type

Single-Use

Fit Type

Ambidextrous

Grade

Powder-Free Exam

Material

Nitrile

Finger Thickness mil

8.2mil

Finger Thickness mm

0.21mm

Palm Thickness mil

6.2mil

Palm Thickness mm

0.16mm

Cuff Thickness mil

5.9mil

Cuff Thickness mm

0.15mm

Color Outer

Gray

Surface Outer

Fully Textured

Surface Inner

DriTek

Length inch

9.5"

Length mm

242mm

Palm Width mm

107mm

Weight in Grams

8.8g

Cuff Type

Beaded

AQL

1.5

Country Origin

China/Malaysia

Industries

Life Science

Yes

Healthcare

Yes

Industrial

Yes

Automotive After Market

Yes

Performance

Tensile Before

15 MPa

Tensile After

16 MPa

Elongation Before

550%

Elongation After

500%

Size Item Number UPC Number Packaging Unit
XS (5 ½ - 6) N260501 0130616489265017 50/Bx 500/Cs
S (6 ½ - 7) N260502 0130616489265024 50/Bx 500/Cs
M (7 ½ - 8) N260503 0130616489265031 50/Bx 500/Cs
L (8 ½ - 9) N260504 0130616489265048 50/Bx 500/Cs
XL (9 ½ - 10) N260505 0130616489265055 50/Bx 500/Cs
2XL (10 ½ - 11) N260506 0130616489265062 50/Bx 500/Cs

ANSI-ISEA-105 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 ANSI-ISEA 105 Level Report No.
Acetic Acid (Glacial) 64-19-7 3 0
Citric Acid (50%) 77-92-9 >240 5
Hydrochloric Acid (37%) 7647-01-0 17 1
Hydrochloric Acid (20%) 7647-01-0 >240 5
Perchloric Acid (70%) 7601-90-3 >60 3
Nitric Acid (70%) 7697-37-2 12 1
Sulfuric Acid (96%) 7664-93-9 10 1
Sulfuric Acid (50%) 7664-93-9 >240 5
Phosphoric acid (85%) 7664-38-2 >240 5
Hydrogen Peroxide (30%) 7722-84-1 >30 2
Ammonium Hydroxide (25%) 1336-21-6 23 1
Sodium Hydroxide (40%) 1310-73-2 >240 5
Sodium Hypochlorite 7681-52-9 >240 5
Ethidim Bromide (5%) 1239-45-8 >240 5
Chloroform 67-66-3 <5 0
DMSO 67-68-5 <5 0
DMSO (10%) 67-68-5 >30 2
Heptane 142-82-5 60 3
Hexane 110-54-3 7 0
Petroleum ether 8032-32-4 61 3
Stoddard Solvent 8052-41-3 24 1
Phenol (0.5%) 108-95-2 >60 3
Xylene 1330-20-7 <5 0
Acetone 67-64-1 <5 0
Acetonitrile 75-05-8 <5 0
Formalin / Formaldehyde 37% 50-00-0 >240 5
2-butoxyethanol 111-76-2 49 2
Diacetone alcohol 123-42-2 44 2
Ethyl alcohol / Ethanol (99%) 64-17-5 11 1
Ethyl alcohol / Ethanol (70%) 64-68-5 >30 2
Isopropanol / IPA (99%) 67-63-0 25 1
Methanol 67-56-1 <5 0

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the ANSI-ISEA 105 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.

EN374-3 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 EN374-3 Level Report No.
Acetic Acid (Glacial) 64-19-7 5 0
Citric Acid (50%) 77-92-9 >240 5
Hydrochloric Acid (37%) 7647-01-0 22 1
Hydrochloric Acid (20%) 7647-01-0 >240 5
Perchloric Acid (70%) 7601-90-3 >60 3
Nitric Acid (70%) 7697-37-2 12 1
Sulfuric Acid (96%) 7664-93-9 9 0
Sulfuric Acid (50%) 7664-93-9 >240 5
Phosphoric acid (85%) 7664-38-2 >240 5
Hydrogen Peroxide (30%) 7722-84-1 >60 3
Ammonium Hydroxide (25% 1336-21-6 70 3
Sodium Hydroxide (40%) 1310-73-2 >240 5
Sodium Hypochlorite 7681-52-9 >240 5
Ethidim Bromide (5%) 1239-45-8 >240 5
Chloroform 67-66-3 0 0
DMSO 67-68-5 <5 0
DMSO (10%) 67-68-5 >30 2
Heptane 142-82-5 84 3
Hexane 110-54-3 10 0
Petroleum ether 8032-32-4 58 2
Stoddard Solvent 8052-41-3 20 1
Phenol (0.5%) 108-95-2 >60 3
Xylene 1330-20-7 <5 0
Acetone 67-64-1 0 0
Acetonitrile 75-05-8 0 0
Formalin / Formaldehyde 37% 50-00-0 >240 5
2-butoxyethanol 111-76-2 46 2
Diacetone alcohol 123-42-2 43 2
Ethyl alcohol / Ethanol (99%) 64-17-5 11 1
Ethyl alcohol / Ethanol (70%) 64-68-5 >30 2
Isopropanol / IPA (99%) 67-63-0 28 1
Methanol 67-56-1 <5 0

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the EN374-3 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.

Product Technologies

Moisture-wicking flock-lined system for drier, cooler, more comfortable hands. Naturally manages sweat for healthier hands and easy donning and doffing.

Sustainable nitrile technology without performance loss.