TF-95RB

TF-95RB
Everyday Sustainable Nitrile Exam Gloves
-
Chemotherapy Tested
-
Fentanyl & Gastric Acid Tested
-
Low Dermatitis Potential
-
SHA Approved
-
British Safety Industrial Federation
-
Instruction for Use
-
EN Food Safe
-
ISO 374-1:2016 Type B JKT
-
EN374-5:2016 VIRUS
-
CE 0493
• The new lighter standard for everyday exam use
• Consistent quality glove to glove
• Beaded cuff allows easy donning and doffing
• EcoTek technology breaks down in landfills in less time
Description
Value and performance hand protection for lab, life science and industrial environments. Now with EcoTek sustainable technology that allows nitrile to reduce waste in landfill 92.6% in only 2.5 years.
Features and Benefits
• EcoTek® Sustainable Technology accelerates landfill breakdown without any performance loss
• Textured surface for excellent wet and dry grip
• Silicone-free for critical environments
• Tear-resistant beaded cuff eases donning
• SHA Dermatologically Approved
• 1.5 AQL exceeds laboratory standards
Typical Applications
For Medical Use
Chemical Handling
Dental
Veterinary
Product Technologies
EcoTek
Yes
Specifications
Glove Type
Single-Use
Fit Type
Ambidextrous
Grade
Powder-Free Exam
Material
Nitrile
Finger Thickness mil
4.7mil
Finger Thickness mm
0.12mm
Palm Thickness mil
3.1mil
Palm Thickness mm
0.08mm
Color Outer
Royal Blue
Surface Outer
Fully Textured
Length inch
9.5"
Length mm
242mm
Palm Width mm
105mm
Weight in Grams
5.0g
Cuff Type
Beaded
AQL
1.5
Country Origin
Malaysia
Industries
Life Science
Yes
Healthcare
Yes
Industrial
Yes
Automotive After Market
Yes
Performance
Tensile Before
14 MPa
Tensile After
14 MPa
Elongation Before
500%
Elongation After
400%
Size | Item Number | UPC Number | Packaging Unit |
---|---|---|---|
XS (5 ½ - 6) | N301341 | 0130616489301319 | 100/Bx 1000/Cs |
S (6 ½ - 7) | N301342 | 0130616489301326 | 100/Bx 1000/Cs |
M (7 ½ - 8) | N301343 | 0130616489301333 | 100/Bx 1000/Cs |
L (8 ½ - 9) | N301344 | 0130616489301340 | 100/Bx 1000/Cs |
XL (9 ½ - 10) | N301345 | 0130616489301357 | 100/Bx 1000/Cs |
2XL (10 ½ - 11) | N301346 | 0130616489301364 | 100/Bx 1000/Cs |
Documents |
|
TF-95RB Datasheet |
ANSI-ISEA-105 Chemical Permeation Breakthrough Times
Chemical | CAS No. | Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 | ANSI-ISEA 105 Level | Report No. |
---|---|---|---|---|
Acetic Acid (Glacial) | 64-19-7 | 8 | 0 | |
Hydrochloric Acid (37%) | 7647-01-0 | <5 | 0 | |
Nitric Acid (70%) | 7697-37-2 | <5 | 0 | |
Sulfuric Acid (96%) | 7664-93-9 | <5 | 0 | |
Phosphoric acid (85%) | 7664-38-2 | >240 | 5 | |
Ammonium Hydroxide (25%) | 1336-21-6 | 36 | 2 | |
Sodium Hydroxide (40%) | 1310-73-2 | >240 | 5 | |
Benzene | 71-43-2 | 0 | 0 | |
Butyl Acetate | 123-86-4 | <5 | 0 | |
Chloroform | 67-66-3 | <5 | 0 | |
DMSO | 67-68-5 | <5 | 0 | |
Heptane | 142-82-5 | 37 | 2 | |
Hexane | 110-54-3 | 22 | 1 | |
Petroleum ether | 8032-32-4 | 17 | 1 | |
Stoddard Solvent | 68797-94-4 | <5 | 0 | |
Xylene | 1330-20-7 | <5 | 0 | |
Acetone | 67-64-1 | <5 | 0 | |
Acetonitrile | 75-05-8 | <5 | 0 | |
Cyclohexanone | 108-94-1 | <5 | 0 | |
2-butoxyethanol | 111-76-2 | <5 | 0 | |
Diacetone alcohol | 123-42-2 | 11 | 1 | |
Ethyl alcohol | 64-17-5 | <5 | 0 | |
Isopropyl alcohol | 67-56-1 | 5 | 0 | |
Methanol | 67-63-0 | <5 | 0 |
The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the ANSI-ISEA 105 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.
EN374-3 Chemical Permeation Breakthrough Times
Chemical | CAS No. | Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 | EN374-3 Level | Report No. |
---|---|---|---|---|
Acetic Acid (Glacial) | 64-19-7 | <5 | ||
Hydrochloric Acid (37%) | 7647-01-0 | <5 | ||
Nitric Acid (70%) | 7697-37-2 | 7 | ||
Sulfuric Acid (96%) | 7664-93-9 | <5 | ||
Phosphoric acid (85%) | 7664-38-2 | >240 | 5 | |
Ammonium Hydroxide (25%) | 1336-21-6 | 50 | 2 | |
Sodium Hydroxide (40%) | 1310-73-2 | >240 | 5 | |
Benzene | 71-43-2 | 0 | ||
Butyl Acetate | 123-86-4 | 0 | ||
Chloroform | 67-66-3 | 0 | ||
DMSO | 67-68-5 | 0 | ||
Heptane | 42-82-5 | 41 | 2 | |
Hexane | 110-54-3 | 16 | 1 | |
Petroleum ether | 8032-32-4 | 23 | 1 | |
Stoddard Solvent | 68797-94-4 | <5 | ||
Xylene | 1330-20-7 | <5 | ||
Acetone | 67-64-1 | 0 | ||
Acetonitrile | 75-05-8 | 0 | ||
Cyclohexanone | 108-94-1 | <5 | ||
2-butoxyethanol | 111-76-2 | <5 | ||
Diacetone alcohol | 123-42-2 | 12 | 1 | |
Ethyl alcohol | 64-17-5 | <5 | ||
Isopropyl alcohol | 67-56-1 | <5 | ||
Methanol | 67-63-0 | <5 |
The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the EN374-3 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.
Product Technologies
![]() Proprietary formula that dramatically accelerates landfill breakdown. Gloves break down 92.6% over 2.5 years without any impact on glove performance. |
PHOTOS |
Coming soon!
Coming soon!